Sterilization methods

Indicates the method(s) of sterilization that can be used for this device prior to device use on the patient.

The Entry LOVs represent the sterilization methods recognized by the CDRH Infection Control Branch. Methods selected should be only those approved for each device by the CDRH Office of Device Evaluation.

Bedeutung der Parameter:

Argument
Code

Parameter 01

Bezeichnung

Parameter 02

Bezeichnung lang
Code Bezeichnung Bezeichnung lang
C101691 Chlorine Dioxide (ClO A sterilization process that uses chlorine dioxide (ClO
C101712 Dry Heat Sterilization A sterilization process that uses high temperature and dry air to kill microorganisms.
C101713 Ethylene Oxide Sterilization A sterilization process that uses ethylene oxide (EtO) gas to kill microorganisms.
C101693 High Intensity Light or Pulse Light Sterilization A sterilization process that
C107419 High-level Disinfectant Sterilization A germicide that inactivates all microbial pathogens, except small numbers of bacterial endospores.
C101689 Hydrogen Peroxide (H A sterilization process that uses radicals that form from  hydrogen peroxide (H
C107418 Liquid Chemical Sterilization A sterilization process that uses liquid chemical as its sterilant to kill microorganisms.
C101694 Microwave Radiation Sterilization A sterilization process that uses nonionizing  radiation at frequencies between 300MHz and 300GHz in the microwave region to kill microorganisms.
C101714 Moist Heat or Steam Sterilization A sterilization process that uses moist air at high temperatures to kill microorganisms.
C107416 Nitrogen Dioxide Sterilization A sterilization process that uses nitrogen dioxide radicals that are formed from dinitrogen tetroxide dimers to kill microorganisms.
C101690 Ozone (O A sterilization process that uses radicals that form from ozone(O
C101697 Peracetic Acid Sterilization A sterilization process that uses the vaporized form of a ch
C101715 Radiation Sterilization A sterilization process that uses radiation such as electron beams, X-rays, gamma rays, or subatomic particles to kill microorganisms.
C101695 Sound Waves Sterilization A sterilization process that uses high-frequency sound waves to kill microorganisms.
C84382 Sterilization Method Validated process used to render product free from viable microorganisms. See ISO/TS 11139.D7
C107417 Supercritical Carbon Dioxide Sterilization A sterilization process that uses supercritical carbon dioxide in combination with a small percentage of additive to kill microorganisms.