FRDSZE
Sterilization methods
Indicates the method(s) of sterilization that can be used for this device prior to device use on the patient.
The Entry LOVs represent the sterilization methods recognized by the CDRH Infection Control Branch. Methods selected should be only those approved for each device by the CDRH Office of Device Evaluation.
Bedeutung der Parameter:
|
Argument
|
Code
|
|
Parameter 01 |
Bezeichnung
|
|
Parameter 02 |
Bezeichnung lang
|
| Code | Bezeichnung | Bezeichnung lang | |
|---|---|---|---|
| C101691 | Chlorine Dioxide (ClO | A sterilization process that uses chlorine dioxide (ClO | |
| C101712 | Dry Heat Sterilization | A sterilization process that uses high temperature and dry air to kill microorganisms. | |
| C101713 | Ethylene Oxide Sterilization | A sterilization process that uses ethylene oxide (EtO) gas to kill microorganisms. | |
| C101693 | High Intensity Light or Pulse Light Sterilization | A sterilization process that | |
| C107419 | High-level Disinfectant Sterilization | A germicide that inactivates all microbial pathogens, except small numbers of bacterial endospores. | |
| C101689 | Hydrogen Peroxide (H | A sterilization process that uses radicals that form from hydrogen peroxide (H | |
| C107418 | Liquid Chemical Sterilization | A sterilization process that uses liquid chemical as its sterilant to kill microorganisms. | |
| C101694 | Microwave Radiation Sterilization | A sterilization process that uses nonionizing radiation at frequencies between 300MHz and 300GHz in the microwave region to kill microorganisms. | |
| C101714 | Moist Heat or Steam Sterilization | A sterilization process that uses moist air at high temperatures to kill microorganisms. | |
| C107416 | Nitrogen Dioxide Sterilization | A sterilization process that uses nitrogen dioxide radicals that are formed from dinitrogen tetroxide dimers to kill microorganisms. | |
| C101690 | Ozone (O | A sterilization process that uses radicals that form from ozone(O | |
| C101697 | Peracetic Acid Sterilization | A sterilization process that uses the vaporized form of a ch | |
| C101715 | Radiation Sterilization | A sterilization process that uses radiation such as electron beams, X-rays, gamma rays, or subatomic particles to kill microorganisms. | |
| C101695 | Sound Waves Sterilization | A sterilization process that uses high-frequency sound waves to kill microorganisms. | |
| C84382 | Sterilization Method | Validated process used to render product free from viable microorganisms. See ISO/TS 11139.D7 | |
| C107417 | Supercritical Carbon Dioxide Sterilization | A sterilization process that uses supercritical carbon dioxide in combination with a small percentage of additive to kill microorganisms. | |
| C101696 | Ultraviolet Light Sterilization | A sterilization process that uses short wavelength radiation to kill microorganisms. |